4 Wing flat roof attic ventilator with insulated base Français
Description
Attic ventilator OP-i412 is conceived for flat roofs. Its sophisticated wings design and openings allow optimal attic ventilation. Its ventilator structure punched openings eliminates all maintenance needs and prevents rodents and birds from getting inside. Its anti-gust deflectors prevents bad weather infiltration from any directions. This model can easily replace 3 conventional gooseneck vents. OP-i412 Ventilator allows an advantageous cooler attic in summer and dryer in winter, extending structural integrity, adding superior interior comfort, creating also energy savings. This static ventilator offers a superior air aspiration and, with the help of wind, produces a chimney effect. Air is continuously exchanged. To determine roof surface that Ventilator OP-i412 can cover, the air space between roof and insulation is required. It is more the opening of the wooden box that will determine, with the ventilator, the net free air evacuation.
Application
Determine ventilator’s emplacement at the center of two trusses and at 4 feet from roof a low wall. Trace, with a chalk, a 12”X12” square for the flashing, insuring to have flashing parallel to roof edge. Cut the opening, remove any obstruction around the hole that would bother ventilator’s installation. Install the base of the ventilator over the opening then aim it. Install the roofing membrane according to the membrane manufacturer's instructions, so as to cover the base of the ventilator. The base is insulated to prevent any risk of condensation. Screw the ventilator to the base, making sure it is level. It is important to all ventilator are of the same model and balance the height thereof to allow adequate ventilation and optimize the performance of ventilation.
Use
Ventilation is required by Canada’s building code. The issue remains in the fact of keeping a fresh attic. Ideally, attic temperature would be, a few degree close, similar to exterior temperature. In summer, using an Optimum ventilator allows heat elimination from the attic. This heat radiates inside and warms up the house. It can also create seepage problems, warp coatings or curl asphalt shingles. Thereby, an air conditioner must work continuously to cool down living areas. In wintertime, interior house air is warmer and contains more vapor pressure, in opposition to the dry and cold attic air. Vapor will have a tendency to migrate to the attic and condensate on cold building structure pieces. This condensation can humidify and compress isolation reducing at the same time the isolation factor and allowing more vapor migration. This humidity leads to ice formation on the roof, mildew and rot of the structure
Dimensions and special features
4 Wing flat roof attic ventilator with insulated base

The ventilator structure is designed galvanized steel. It covered with baked powder paint.

PRODUCT

DIMENSIONS

EVACUATION

NUMBER OF DEFLECTORS

STEEL GAUGE USED

A

B

C

D

OP-i412

30,4 cm • 12”

49,5 cm • 19,5”

25,4 cm • 10”

27,9 cm • 11”

0,09 m² • 144 in.²

4

22 - 24 & 26

OP-i414

35,6 cm • 14”

54,6 cm • 21,5”

25,4 cm • 10”

34,2 cm • 13,5"

0,12 m² • 196 in.²

4

22 - 24 & 26

OP-i516

40,6 cm • 16”

59,6 cm • 23,5”

31,7 cm • 12,5”

40 cm • 15,75”

0,16 m² • 256 in.²

5

22 - 24 & 26

OP-i518

45,7 cm • 18”

64,7 cm • 25,5”

31,7 cm • 12,5”

42,5 cm • 16,75”

0,20 m² • 324 in.²

5

22 - 24 & 26

OP-i620

50,8 cm • 20”

69,8 cm • 27,5”

37,5 cm • 14,75”

41,3 cm • 16,25”

0,26 m² • 400 in.²

6

22 & 24

OP-i622

55,8 cm • 22”

74,9 cm • 29,5”

37,5 cm • 14,75”

42,5 cm • 16,75”

0,31 m² • 484 in.²

6

22 & 24

OP-i724

60,9 cm • 24”

80 cm • 31,5”

43,8 cm • 17,25”

43,2 cm • 17”

0,37 m² • 576 in.²

7

22 & 24

  • Models OP-i412 to OP-i724 are available with filter if needed.
  • Models OP-i414, OP-i516, OP-i518, OP-i620, OP-i622 and OP-i724 are available on special orders only.
  • We can manufacture other dimension on request.
  • There are other color choice available, see our website.

The exhaust area based on air evacuation ratio.

Warranty
The customer shall verify of the suitability of this product for the intended purpose. Applicator's skill, weather and surface conditions being beyond manufacturer's control, we limit our liability to replacement of defective material only in sealed container, within 1 year of proof of purchase. FOB plant. For more details refer to:http://www.condor.pro/optimum/Warranty_Optimum.pdf

4 Wing flat roof attic ventilator with insulated base
Ecologic
The national building code requires adequate ventilation of the attic, according to the minimum standard of Section 9.19.1 or according to CSA CAN3-A93-M82.
It is necessary to ensure that the base is completely watertight. That all joints on base are well covered by proper products making them completely watertight. Make sure to pass on the original joint located at the base of the flashing
Optimum's ventilator are avalable in :
Black, Grey, Brown and White
Optimum's ventilator are avalable in : Black, Grey, Brown and White
Others Optimum's colours available by special orders
 
PDFdownload PDF version